Skip links

IDS-205G – Managed Industrial Ethernet Switch with Gigabit Fiber (4 x 10/100/1000Base-T RJ45 and 1 x 1000Base-X SC/ST)

cx 100m m2lc lg 4
  • 4 port 10/100/1000Base-T ( RJ45 ) for Gigabit and Fast Ethernet devices
  • 1 port 1000Base-X SC/ST fiber connection
  • IP Manageability, VLAN and resiliency management
  • Compact, corrosion resistant case attaches to a standard DIN Rail
  • Redundant dual power input 12/24/48 VDC
  • Out-of-band management via RJ45
  • Programmable Controller safety and Hazardous Location Certification
  • -40 to 75C industrial operating temperature ( XT Models )

Jetzt unverbindlich anfragen!

Preise, Verfügbarkeit oder individuelle Beratung unverbindlich anfragen.

[elfsight_form_builder id=”1″]

Overview

The IDS-205G is a 5 port Managed Ethernet Switch that can operate in industrial environments providing advanced performance and enabling real-time deterministic network operation. Four 10/100/1000-Base-T Ethernet ports are available for networking Gigabit and Fast Ethernet devices. One 1000Base-X fiber connection is available to extend Gigabit Ethernet operating distances over fiber.

In industrial plants, where high levels of electromagnetic interference ( EMI ) is a common phenomenon, utilizing fiber is critical.  EMI can cause data corruption over copper-based Ethernet links. However, data transmitted over fiber optic cable is completely immune to this type of noise ensuring optimal data transmission across the plant floor.

Perle Industrial-grade Ethernet Switches are designed to stand up to extreme temperatures, surges, vibrations, and shocks found in industrial automation, government, military, oil and gas, mining and outdoor applications.

With over 30 models, the Perle IDS-205G offers a choice of connectors, fiber types, temperature support and operating distances.

The simple Plug and Play installation available in Perle’s Fast Setup feature gets your Ethernet devices networked immediately. CCNA ( Cisco Certified Network Associate ) and CCNP ( Cisco Certified Network Professional ) trained engineers will appreciate the familiar Command Line Interface ( CLI ) via in-band Telnet or the out-band serial console port.

An IPv6 address can be used to manage the IDS-205G which also supports a comprehensive set of management functions, such as P-Ring, management VLAN, QoS, RMON, N:1 port mirroring and local alert log.

These rugged fan-less switches that are hardened to provide superior reliability in -10 to 60°C.  In addition, every component on every industrial (XT) model has been designed and tested to handle operating temperatures between -40 and 75C.

All Perle Industrial Ethernet Switches only use high-end components from the leading chip manufacturers to ensure the highest level of durability and reliability. In addition, all units have a corrosion resistance aluminum case and dual redundant power input with reverse polarity and overload protection.

For over 35 years Perle has been designing industrial hardware. This expertise was used to design the toughest Ethernet switches on the market that will keep your system running for years to come.

IDS-205G Industrial Managed DIN Rail Switch Features

Simple deployment

Zero-touch discovery using Dynamic Host Control Protocol (DHCP), Perle’s “Fast Setup” for first time installation, provides simple deployment in Ethernet environments.

Resiliency 

  • STP and RSTP protocols for fast recovery.
  • Perle’s P-Ring protocol for fast convergence in ring topologies

Manageability 

  • Web Device Manager, Telnet, SNMP and Perle’s PerleView NMS for centralized management
  • In-band management via RJ45 port
  • Use an IPv4 or IPv6 address

Rugged design for harsh environments

  • Corrosion resistant case
  • Programmable Controller Safety certified
  • Certified for hazardous locations
  • Extended industrial temperature models

Reliable operation

  • Fan-less, no moving parts
  • Dual power input. Connect to separate power sources for redundancy.
    • Reverse polarity protection
    • Overload current protection
  • Handles vibration and shock conditions found in industrial environments

Real-time Ethernet performance

  • Fast wire-speed , store and forward switching
  • Auto-sensing for speed and duplex
  • Auto-mdi/mdix-crossover works with straight and crossover cables

Energy Efficient Ethernet ( EEE )

Energy Efficient Ethernet (EEE) as per 802.3az provides power savings during idle network activity.


Features

Performance Features
Port Auto-sensing

Auto-sensing of port speed and auto-negotiation of duplex on all switch ports for optimizing bandwidth

Auto MDI/MDIX

Medium-dependent interface crossover ( Auto-MDIX ) capability on 10/100 and 10/100/1000 mbps  interfaces that enables the interface to automatically detect the required cable type ( straight thru or crossover ) and to configure the connection appropriately

802.3x flow control

IEEE 802.3x flow control on all ports. ( The switch does not initiate pause frames )

Storm Control

Storm control prevents traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm on one of the physical interfaces. A LAN storm occurs when packets flood the LAN, creating excessive traffic and degrading network performance. Storm Control enables limits to be placed on broadcast, multicast and unicast traffic

Static MAC Addressing

This feature enables the manual configuration of the MAC addresses on a per port basis. Flooding is prevented by retaining MAC entries across a reboot of the switch.

Port Blocking

Port Blocking provides the ability to block the flooding of unknown layer 2 unicast and multicast traffic on an Interface

IPV4 IGMP Snooping

Internet Group Management Protocol ( IGMP ) constrains the flooding of multicast traffic by dynamically configuring Layer 2 interfaces so that multicast traffic is forwarded to only those interfaces associated with IP multicast devices.

IGMPv1, v2, v3, IGMP snooping querier mode, IGMP report suppression, topology change notification and robustness variable features are supported

Port Quick Disconnect

In some network environments, it is desirable to move an Ethernet from one switch port to another and have the device come on-line quickly. The Port Quick Disconnect feature if enabled, provides an immediate age-out of the MAC addresses learned on the port when the port status changes from a link-up to a link-down state

Manageability Features
Web Device Manager

The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch. Unlike competitive products, Java applet technology is not required or used

Command Line Interface ( CLI )

A familiar text-based Command Line Interface that is based on accepted industry standard syntax and structure. Ideal for CCNA and CCNP trained engineers, this interface is available via in-band Telnet or the out-band serial console port

SNMP

Manage the switch with an snmp compatible management station that is running platforms such as HP Openview or Perle’s PerleVIEW NMS. SNMP V1 and V2C

PerleVIEW

PerleVIEW is Perle’s SNMP-based network management system that provides a view of the network with a large scale of Perle networking devices.

IPv6

Manage with an IPv4 or IPV6 address

DHCP Client Auto-Configuration

Automates configuration of switch information such as IP address, default gateway, hostname and Domain Name System ( DNS ) as well as TFTP server names. Firmware and configuration file locations are provided through options 54, 66, 67, 125 and 150

DHCP Relay

DHCP Relay is used for forwarding requests from DHCP clients when they are not on the same physical subnet. As a DHCP relay agent the switch operates as a Layer 3 device that forwards DHCP packets between clients and servers.

DHCP Option 82 Insertion

Normally used in metro or large enterprise deployments DHCP Option 82 insertion is used to provide additional information on “physical attachment” of the client.  As per RFC 3046, option 82 enables additional pre-defined information to be inserted into the DHCP request packet  ( for DHCP Servers that support this option )

LLDP

LLDP-Link Layer Discovery Protocol as per IEEE 802.1AB is a neighbor discovery protocol that is used for network devices to advertise information about themselves to other devices on the network. This protocol runs over the data-link layer, which allows two systems running different network layer protocols to learn about each other ( via TLVs – Type-Length-Value )

File Download

Firmware can be transferred via TFTP or HTTP. Text-based files that can be created or edited by common text editors.

Availability and Redundancy Features
Spanning Tree Protocol ( STP )

IEEE 802.1D now incorporated in IEEE 802.1Q-2014, STP prevents bridge loops and the broadcast radiation that results from them.

Rapid Spanning Tree Protocol ( RSTP )

Interoperable with STP, RSTP ( IEEE 802.1w ) takes advantage of point-to-point wiring and provides rapid convergence of the spanning tree. Reconfiguration of the spanning tree can occur in less than 1 second

P-Ring

P-Ring provides an easy to use method for configuring a ring network using standard spanning tree protocols.

Prevents a switch loop scenario in a ring topology.

Link Standby A link recovery feature using a primary and backup link. Provides a simple alternative to spanning tree protocols for link redundancy
VLAN Features
VLAN Range

Up to 256 VLANS across a VLAN ID range of 1 to 4000

VLAN Interfaces

Perle switches provide the ability to configure management VLAN interfaces. This enables network administrators to access the switch’s management interface from separate VLAN networks

Quality of Service ( QoS ) and Class of Service ( CoS ) Features
Classification

IP ToS/DSCP and IEEE 802.1p CoS

Congestion Avoidance

Weighted Fair Queuing or Strict Queuing

Egress Queues and scheduling
  • 4 traffic class queues per port
  • output queue mapping
  • DSCP to output queue mapping
Monitoring Features
Port Mirroring

N:1 Port Mirroring is a method of monitoring network traffic. With port mirroring enabled, the switch sends a copy of one or more ports to a predefined destination port. Selection of Transmit, Receive frames or both can be made

RMON

RMON statistics provided for statistics, history, alarms and events for network monitoring and traffic analysis

Syslog

Facility for logging systems messages to an external SYSLOG server

Alert Log

Facility for logging systems messages locally

Traceroute

Layer 2 traceroute to identify the path that a frame takes from source to destination

Virtual cable test

A test that enables the detection of potential copper cabling issues such as pair polarity pair swaps and excessive pair skew as well as any opens, shorts or any impedance mismatch. Will report the distance in the cable to the open or short.

Power Supply Monitoring

Provides the status of power supplies of the switch

Alarm Processing

The switch can monitor global switch conditions as well as individual ports. These alarms can be configured to send messages to ;

  • an internal log file
  • external Syslog server
  • SNMP trap server
  • An external alarm device such as a bell, light or other signaling device via the switch’s built-in dry contact alarm relay

Global Status Monitoring Alarms

  • Dual power supply alarm

Port Status Monitoring Alarms

  • Link Fault Alarm ( IE loss of signal )
  • Port not forwarding alarm
  • Port not operating alarm ( failure upon start up tests )
  • FCS Bit error rate alarm
Alarm Relay

When enabled, energizes the built-alarm relay triggering an external alarm circuit such as a bell, light or other signaling device according to alarm conditions set

Management and Standards
IEEE Standards

IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-T(X) and 100Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.1AB LLDP

SNMP MIB Objects

IEEE8021-PAE-MIB
NTPv4-MIB
IEEE8021-SPANNING-TREE-MIB
SYSAPPL-MIB
LLDP-EXT-MED-MIB
SNMP-COMMUNITY-MIB
LLDP-EXT-MED-MIB
IGMP-STD-MIB
IEEE8021-MSTP-MIB
Q-BRIDGE-MIB
LLDP-EXT-DOT3-MIB
IF-MIB
RSTP-MIB
DIFFSERV-DSCP-TC
LLDP-EXT-DOT1-MIB
IEEE8021-TC-MIB
LLDP-MIB
RMON2-MIB
ENTITY-MIB
P-BRIDGE-MIB
PERLE-LOGIN-MIB
PERLE-ALERT-MIB
PERLE-IP-SSH-MIB
PERLE-IP-PROTOCOLS-MIB
PERLE-USER-MIB
PERLE-SMI
PERLE-MAC-NOTIFICATION-MIB
PERLE-SYSINFO-MIB
PERLE-LINKSTANDBY-MIB
PERLE-AAA-MIB
perle-AAA.MIB
PERLE-IPV6-MIB
PERLE-LOGGING-MIB
PERLE-VLAN-MIB
PERLE-IF-MIB
PERLE-ENTITY-VENDORTYPE-OID-MIB
PERLE-ERR-DISABLE-MIB
PERLE-SWITCH-PLATFORM-MIB
PERLE-ENVMON-MIB
PERLE-TIME-MIB
PERLE-PTP-MIB
PERLE-P-RING-MIB
PERLE-SNMP-MIB
PERLE-FILE-TRANSFER-MIB
PERLE-SWITCH-GLOBAL-MIB
PERLE-BOOT-MIB
PERLE-PRODUCTS-MIB
PERLE-BANDWIDTH-CONTROL-MIB
PERLE-IP-TELNET-MIB
PERLE-GVRP-MIB
PERLE-PORT-SECURITY-MIB
PERLE-DHCP-SERVER-MIB
PERLE-GARP-MIB
PERLE-ARCHIVE-MIB
PERLE-NTP-MIB
PERLE-SSL-MIB
PERLE-IGMP-MIB
PERLE-ACL-MIB
PERLE-POE-MIB
PERLE-RELOAD-MIB
PERLE-ENTITY-ALARM-MIB
PERLE-IPV6-NEIGHBOR-MIB
PERLE-DOT1X-AUTH-MIB
PERLE-TC
PERLE-DHCP-CLIENT-MIB
PERLE-LINE-MIB
PERLE-ARP-MIB
PERLE-GMRP-MIB
PERLE-MLD-MIB
PERLE-IP-HTTP-MIB
PERLE-PORT-MONITOR-MIB
PERLE-SpTreeExtensions-MIB
PERLE-IP-MIB


Hardware Specs

Hardware Features & Technical Specifications: IDS-205G Industrial Managed DIN Rail Switch

Power

Dual Power Input

Both inputs draw power simultaneously. If one power source fails, the other live source can, acting as a backup, supply enough power to meet the operational needs of the switch.

12/24/48 VDC Nominal. (9.6 to 60 VDC)

Power Connector

4-Pin Removable Terminal Block.

Grounding screw on metal chassis

Terminal Block Image

Maximum Current Consumption @24 vDC 0.14 amps
Maximum Power Consumption @24 vDC 3.4 watts

Overload Current Protection

Fused overload current protection

Reverse polarity protection

The positive and negative inputs can be reversed providing safe and simple power connectivity.

Access Ports

RJ45

4 shielded RJ45 ports for 10/100/1000Base-T up to 100 meters (328 ft.)

Auto-negotiation

Auto-MDI/MDIX-crossover for use with either crossover over straight-through cable types

Ethernet isolation 1500 V

RJ45 Serial Console port

RJ45 DTE
Optional rolled and straight thru RJ45 cables and DB adapters are available

Gigabit Fiber port

1000Base-x fiber port models

Duplex SC or ST connector

  • Multimode 50/125 or 62.5/125 micron fiber cable
  • Single mode 9/125 micron fiber cable

Simplex (BIDI, single strand) SC connector

  • Multimode 50/125 or 62.5/125 micron fiber cable
  • Single mode 9/125 micron fiber cable

PC and UPC type patch cords supported.

Fiber Port Specs

Fiber Type

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)

IEEE

Core
Size
(um)

Modal
Bandwidth
(MHz* Km)

Maximum Operating
Distance

Min

Max

Min

Max

MMF
(Duplex SC/ST)

-9.5

-4.0

-17.0

-3.0

7.5

850

1000Base-SX

62.5

160

220 m
(722 ft.)

62.5

200

275 m
(902 ft.)

50

400

500 m
(1,640 ft.)

50

500

550 m
(1,804 ft.)

50

2000

1000 m
(3281 ft.)

MMF
(Duplex SC/ST)

-6.0

0.0

-17.0

0.0

11.0

1310

1000Base-LX

62.5

160

2 km
(1.2 mi)

50

500

1 km
(3280ft)

MMF
(simplex SC)
-10.0 -4.0 -17.0 -3.0 7.0

1310 / 1550

1550 / 1310

1000Base-BX-U
1000Base-BX-D

62.5

50

500 500 m
(1,640 ft)

SMF
(Duplex SC/ST)

-9.5

-3.0

-20.0

-3.0

10.5

1310

1000Base-LX/LH

9

**

10 km
(6.2 mi)

SMF
(Simplex SC)

-9.0

-3.0

-20.0

-3.0

11.0

1310 / 1490
1490 / 1310

1000Base-BX-U
1000Base-BX-D

9

**

10 km
(6.2 mi)

SMF
(Simplex SC)

-8.0

-3.0

-22.0

-3.0

14.0

1310 / 1490
1490 / 1310

1000Base-BX-U
1000Base-BX-D

9

**

20 km
(12.4 mi)

SMF
(Duplex SC/ST)

-2.0

2.0

-23.0

-3.0

21.0

1310

1000Base-EX

9

**

40 km
(24.9 mi)

SMF
(Simplex SC)

-3.0

2.0

-23.0

-3.0

20.0

1310 / 1490
1490 / 1310

1000Base-BX-U
1000Base-BX-D

9

**

40 km
(24.9 mi)

SMF
(Duplex SC/ST)

-2.0

5.0

-23.0

-3.0

21.0

1550

1000Base-ZX

9

**

70 km
(43 mi)

SMF
(Simplex SC)

-2.0

3.0

-26.0

-3.0

24.0

1510 / 1590
1590 / 1510

1000Base-BX-U
1000Base-BX-D

9

**

80 km
(50 mi)

SMF
(Duplex SC/ST)

0.0

5.0

-32.0

-9.0

32.0

1550

1000Base-ZX

9

**

120 km
(74.6 mi)

SMF
(Simplex SC)

-3.0

2.0

-34.0

-9.0

31.0

1510 / 1590
1590 / 1510

1000Base-BX-U
1000Base-BX-D

9

**

120 km
(74.6 mi)

SMF
(Duplex SC/ST)

2.0

5.0

-34.0

-9.0

36.0

1550

1000Base-ZX

9

**

160 km
(100 mi)

* 1db/km multimode fiber cable
** as per ITU-T G.652 SMF specifications

Alarms

Alarm Relay

  • NC (Normally Closed) dry contact.
  • 1A @ 24V
Switch Properties

Standards

IEEE 802.3 for 10Base-T

IEEE 802.3u for 100Base-T(X)

IEEE 802.3ab for 1000Base-T

IEEE 802.3z for 1000BaseX

Energy Efficient Ethernet (EEE) as per 802.3az.

IEEE 802.3x for Flow Control

Processing Type

Store and Forward

MAC Address Table Size

8K

VLAN ID range

1 to 4000

IGMP groups

1024

Packet Buffer Memory

1 Mbit

Jumbo Frame Size

10 KB

Indicators

Power

This LED is turned on when the appropriate level of voltage is applied to one or both of the power inputs 

System

Indicates whether the switch O/S is operating normally

RJ45 Ethernet

These integrated colored LEDs indicate link, activity and speed for each port.

Fiber Link

Fiber link LED indicates Link and Data Activity

Alarm

The alarm LED (Red) will be turned on under alarm conditions

P-Ring Master LED

Status of the P-Ring Master

Backup Network Coupling

Indicates whether or not the “Backup Network Coupling” feature is enabled (Redundant links connecting two P-Ring networks)

Environmental Specifications
MTBF 277,426 Hours
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C

Operating Temperature Ranges

Standard temperature models (Std): -10° C to 60° C (14° F to 140° F).

XT Industrial extended temperature models (Ind) : -40° C to 75° C  (-40 F to 167° F)

Storage Temperature Range

Minimum range of -25° C to 75° C (-13° F to 167° F). -40 C to 85 C (-40 F to 185 F) for industrial extended temperature models

Operating Humidity Range

5% to 90% non-condensing

Storage Humidity Range

5% to 95% non-condensing

Maximum Heat Output 11.6 Btu/hr

Operating Altitude

Up to 3,048 meters (10,000 feet)

Chassis

Metal with an IP20 ingress protection rating

Din Rail Mountable

DIN Rail attachment included. Mounts to standard 35 mm DIN rail in accordance with DIN EN 60175.

Removable to accommodate optional Panel/Wall mount kit

Product Weight and Dimensions

Weight

0.61kg (1.34 lbs)

Dimensions

45 x 130 x 121mm

Packaging

Shipping Weight

0.76kg (1.76 lbs)

Shipping Dimensions

170 x 260 x 70 mm

Standards and Certifications

Laser Safety

EN 60825-1:2007

Fiber optic transmitters on this device meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11.

Safety

UL 60950-1

IEC 60950-1:2005+A1:2009 and

EN 60950-1:2006+A11:2009+A1:2010+A12:2011

CE Mark

UL 61010-1 and UL 61010-2-201 (Standard for Safety for Programmable Controllers)

Emissions

FCC 47 Part 15 Class A

CISPR 22:2008/EN55022:2010 (Class A)

CISPR 24:2010/EN 55024:2010

EMC and Immunity

CISPR 24:2010/EN 55024:2010
IEC/EN 61000-4-2 (ESD) :
IEC/EN 61000-4-3 (RS)
IEC/EN 61000-4-4 (EFT) :
IEC/EN 61000-4-5 (Surge)
IEC/EN 61000-4-6 (CS)
IEC/EN 61000-4-8
IEC/EN 61000-6-2 (General Immunity in Industrial Environments)

Industrial Safety

UL 61010-1 and UL 61010-2-201 (Standard for Safety for Programmable Controllers). Formerly known as UL508 (Safety standard for Industrial Control Equipment)

Hazardous Locations (Hazloc)

ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D (formerly known as UL 1604)

ATEX Class 1 Zone 2

Environmental

Reach, RoHS and WEEE Compliant

Other

ECCN: 5A991

HTSUS Number: 8517.62.0050

CCATS: G167960

5 year Warranty

Contents Shipped

Industrial Ethernet Switch with DIN Rail attachment
Terminal block
Installation guide


Application Diagrams

IDS-205G Industrial Switch Diagram
IDS-105F Industrial Switch Network Diagram
Single Mode / Single Strand ( WDM ) Fiber

Connecting devices over a single fiber strand ( also referred to as “Bi-Directional” BiDi or Simplex)

To reduce costs, or where there are limits on available fiber, Wavelength-Division Multiplexing (WDM) technology may be utilized. WDM uses separate transmit and receive frequencies to communicate on a single fiber strand. WDM technology relies on the fact that optical fibers can carry many wavelengths of light simultaneously without interaction between each wavelength. Thus, a single fiber can carry many separate wavelength signals or channels simultaneously. WDM systems are divided into different wavelength patterns, conventional/coarse (CWDM) and dense (DWDM).

Single Mode Fiber Diagram

When Single Strand fiber is used, you will need an “Up” side and a “Down” side when interconnecting fiber devices.

Perle offers a wide variety of Single Fiber (“Up/Down”) Ethernet Switches and Media Converters for use with single strand of fiber.


Ordering Details

Select a Model to obtain a Part Number – IDS-205G

Operating Temperature (Std) = -10° C to 60° C (14° F to 140° F)
All Models have 4 x 10/100/1000Base-T ( RJ45 ) Connectors

Model

Choose your Fiber Connection from the table below
1000Base-X Duplex Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-205G-CMD05

1 x Duplex SC

-9.5

-4.0

-17.0

-3.0

7.5

850

MMF

550 m
(1,804 ft.)

IDS-205G-TMD05

1 x Duplex ST

-9.5

-4.0

-17.0

-3.0

7.5

850

MMF

550 m
(1,804 ft.)

IDS-205G-CMD2

1 x Duplex SC

-6.0

0.0

-17.0

0.0

11.0

1310

MMF

2 km
( 1.2 mi )

IDS-205G-TMD2

1 x Duplex ST

-6.0

0.0

-17.0

0.0

11.0

1310

MMF

2 km
( 1.2 mi )

IDS-205G-CSD10

1 x Duplex SC

-9.5

-3.0

-20.0

-3.0

10.5

1310

SMF

10 km
( 6.2 mi )

IDS-205G-TSD10

1 x Duplex ST

-9.5

-3.0

-20.0

-3.0

10.5

1310

SMF

10 km
( 6.2 mi )

IDS-205G-CSD40

1 x Duplex SC

-2.0

2.0

-23.0

-3.0

21.0

1310

SMF

40 km
( 24.9 mi )

IDS-205G-TSD40

1 x Duplex ST

-2.0

2.0

-23.0

-3.0

21.0

1310

SMF

40 km
( 24.9 mi )

IDS-205G-CSD70

1 x Duplex SC

-2.0

5.0

-23.0

-3.0

21.0

1550

SMF

70 km
( 43 mi )

IDS-205G-TSD70

1 x Duplex ST

-2.0

5.0

-23.0

-3.0

21.0

1550

SMF

70 km
( 43 mi )

IDS-205G-CSD120

1 x Duplex SC

0.0

5.0

-32.0

-9.0

32.0

1550

SMF

120 km
( 74.6 mi )

IDS-205G-TSD120

1 x Duplex ST

0.0

5.0

-32.0

-9.0

32.0

1550

SMF

120 km
( 74.6 mi )

IDS-205G-CSD160

1 x Duplex SC

2.0

5.0

-34.0

-9.0

36.0

1550

SMF

160 km
( 100 mi )

IDS-205G-TSD160

1 x Duplex ST

2.0

5.0

-34.0

-9.0

36.0

1550

SMF

160 km
( 100 mi )

Operating Temperature (Ind) = -40° C to 75° C ( -40 F to 167° F )
All Models have 4 x 10/100/1000Base-T ( RJ45 ) Connectors

Model

Choose your Fiber Connection from the table below
1000Base-X Duplex Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-205G-CMD05-XT

1 x Duplex SC

-9.5

-4.0

-17.0

-3.0

7.5

850

MMF

550 m
(1,804 ft.)

IDS-205G-TMD05-XT

1 x Duplex ST

-9.5

-4.0

-17.0

-3.0

7.5

850

MMF

550 m
(1,804 ft.)

IDS-205G-CSD10-XT

1 x Duplex SC

-9.5

-3.0

-20.0

-3.0

10.5

1310

SMF

10 km
( 6.2 mi )

IDS-205G-TSD10-XT

1 x Duplex ST

-9.5

-3.0

-20.0

-3.0

10.5

1310

SMF

10 km
( 6.2 mi )

* 1db/km multimode 50/125 micron fiber cable

 

Single Fiber ( Simplex / BiDi ) Models Recommended use in pairs

Operating Temperature (Std) = -10° C to 60° C (14° F to 140° F)
All Models have 4 x 10/100/1000Base-T ( RJ45 ) Connectors

Model

Choose your Fiber Connection from the table below
1000Base-X Simplex ( BiDi ) Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)
TX / RX

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-205G-CMS05U

1 x Simplex SC

-10.0

-4.0

-17.0

-3.0

7.0

1310 / 1550

MMF

500 m
(1,640 ft)

IDS-205G-CMS05D

1 x Simplex SC

-10.0

-4.0

-17.0

-3.0

7.0

1550 / 1310

MMF

500 m
(1,640 ft)

IDS-205G-CSS10U

1 x Simplex SC

-9.0

-3.0

-20.0

-3.0

11.0

1310 / 1490

SMF

10 km
( 6.2 mi )

IDS-205G-CSS10D

1 x Simplex SC

-9.0

-3.0

-20.0

-3.0

11.0

1490 / 1310

SMF

10 km
( 6.2 mi )

IDS-205G-CSS20U

1 x Simplex SC

-8.0

-3.0

-22.0

-3.0

14.0

1310 / 1490

SMF

20 km
( 12.4 mi )

IDS-205G-CSS20D

1 x Simplex SC

-8.0

-3.0

-22.0

-3.0

14.0

1490 / 1310

SMF

20 km
( 12.4 mi )

IDS-205G-CSS40U

1 x Simplex SC

-3.0

2.0

-23.0

-3.0

20.0

1310 / 1490

SMF

40 km
( 24.9 mi )

IDS-205G-CSS40D

1 x Simplex SC

-3.0

2.0

-23.0

-3.0

20.0

1490 / 1310

SMF

40 km
( 24.9 mi )

IDS-205G-CSS80U

1 x Simplex SC

-2.0

3.0

-26.0

-3.0

24.0

1510 / 1590

SMF

80 km
( 50 mi )

IDS-205G-CSS80D

1 x Simplex SC

-2.0

3.0

-26.0

-3.0

24.0

1590 / 1510

SMF

80 km
( 50 mi )

IDS-205G-CSS120U

1 x Simplex SC

-3.0

2.0

-34.0

-9.0

31.0

1510 / 1590

SMF

120 km
( 74.6 mi )

IDS-205G-CSS120D

1 x Simplex SC

-3.0

2.0

-34.0

-9.0

31.0

1590 / 1510

SMF

120 km
( 74.6 mi )

Operating Temperature (Ind) = -40° C to 75° C ( -40 F to 167° F )
All Models have 4 x 10/100/1000Base-T ( RJ45 ) Connectors

Model

Choose your Fiber Connection from the table below
1000Base-X Simplex ( BiDi ) Fiber

Fiber
Connector

Transmit
(dBm)

Receive
(dBm)

Power
Budget
(dB)

Wavelength
(nm)
TX / RX

Fiber
Type

Operating
Distance

Min

Max

Min

Max

IDS-205G-CSS10U-XT

1 x Simplex SC

-9.0

-3.0

-20.0

-3.0

11.0

1310 / 1490

SMF

10 km
( 6.2 mi )

IDS-205G-CSS10D-XT

1 x Simplex SC

-9.0

-3.0

-20.0

-3.0

11.0

1490 / 1310

SMF

10 km
( 6.2 mi )

Industrial Ethernet Switch Accessories

Panel Mount kit PM3

Brackets for attaching 30 to 75 mm wide Perle IDS industrial switches inside a control panel or to a wall for wall.

Rack Mount Kit RM4U

Bracket for mounting Perle DIN Rail switches in a standard 19” rack. Occupies “4U” of vertical rack space. 275 mm ( 10 inches ) deep

UNO-PS/1AC/24DC/150W Power Supply

UNO-PS/1AC/24DC/150W Power Supply – DIN-Rail 24 VDC , 150 Watt power supply with universal 85 to 264 VAC, -25 to 70°C extended operating temperature. Power Supply Specifications.

DBA0020C

RJ-45F to DB-9F crossover (DTE) adapter for Perle serial console ports with Sun/Cisco pinout.  #1100300-10

Return to top of page