Overview
The DT-TELE-SHDSL Surge Protector was designed to meet the special requirements of SHDSL data transmission. It is specifically designed to provide Lightning, RFI, ESD and transient surge protection for maximum data security with minimum signal attenuation.
Surge protection for SHDSL systems
Reliable telecommunications are indispensable in today’s industry. The sensitive systems used in these cases work with high frequencies at low signal levels and are networked over a wide area. Surge voltages here quickly lead to largescale failures and, in the worst-case scenario, data loss. The SHDSL Surge Protector takes the form of an adapter that can be easily installed between incoming telecommunications cables and a modem. The pluggable connection ensures fast and flexible installation and only needs to be grounded by way of the black cable or DIN rail base.
Attachment plug with surge protection for two SHDSL telecommunications interfaces (ports). Connection: RJ45 (RJ12/RJ11) and plug-in screw terminal block (COMBICON). Alternatively, can be snapped onto a DIN rail.





Hardware Specs
DT-TELE-SHDS Technical Specifications
Ambient Conditions | |
---|---|
Ambient temperature (operation) | -40 °C … 85 °C |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Degree of protection | IP20 |
Protective circuit | |
IEC test classification | B2 |
C1 | |
C2 | |
C3 | |
D1 | |
Maximum continuous voltage UC | 185 V DC |
Rated current | ≤ 380 mA (25 °C) |
Operating effective current IC at UC | ≤ 6 µA |
Residual current IPE | ≤ 4 µA |
Nominal discharge current In (8/20) µs (Core-Core) | ≤ 5 kA |
Nominal discharge current In (8/20) µs (core-earth) | ≤ 5 kA |
Total discharge current Itotal (8/20) µs | 10 kA |
Nominal pulse current Ian (10/700) µs (Core-Core) | 150 A |
Nominal pulse current Ian (10/700) µs (Core-Earth) | 150 A |
Voltage protection level Up (core-core) | 250 V (B2 – 100 A) |
≤ 250 V (C1 – 500 A) | |
≤ 410 V (C2 – 5 kA) | |
Voltage protection level Up (core-ground) | ≤ 580 V (B2 – 100 A) |
≤ 580 V (C1 – 500 A) | |
Response time tA (core-core) | ≤ 100 ns |
Response time tA (core-earth) | ≤ 100 ns |
Input attenuation aE, sym. | typ. 0.3 dB (≤ 2,8 MHz / 100 Ω) |
typ. 3 dB (≤ 25 MHz / 100 Ω) | |
Cut-off frequency fg (3 dB), sym. in 100 Ohm system | 25 MHz |
Capacity (core-core) | 55 pF |
Capacity (core-earth) | 7 pF |
Surge protection fault message | None |
Impulse durability (conductor-conductor) | C1 – 1 kV/500 A |
Impulse durability (conductor-ground) | B2 – 4 kV/100 A |
C1 – 1 kV/500 A | |
C2 – 10 kV/5 kA | |
VDE requirement class | B2 |
C1 | |
C2 | |
C3 | |
D1 | |
Maximum continuous voltage UC | 130 V AC |
Pulse discharge current Iimp (10/350) µs | 2.5 kA (Number of pulses category D1) |
Nominal pulse current Ian (10/1000) µs (Core-Core) | 100 A |
Nominal pulse current Ian (10/1000) µs (Core-Earth) | 100 A |
Voltage protection level Up (core-core) | ≤ 250 V (C3 – 100 A) |
Voltage protection level Up (core-ground) | ≤ 790 V (C2 – 5 kA) |
≤ 300 V (C3 – 100 A) | |
Resistance in series | 3.3 Ω 20 % |
Impulse durability (conductor-conductor) | C2 – 10 kV/5 kA |
B2 – 4 kV/100 A | |
Impulse durability (conductor-ground) | D1 – 1 kA |
Standards and Regulations | |
Standards / specifications | IEC 61643-21 2002 |
IEC 61643-21 | |
General | |
Housing material | Zinc die-cast |
Color | silver/black |
Mounting type | Connection-specific attachment plug and DIN rail, 35 mm |
Design | Attachment plug for DIN rail mounting |
Number of positions | 4 |
Direction of action | Line-Line & Line-Ground/Shield |
Standards for cearances and creepage distances | IEC 60664-1 |
VDE 0110-1 | |
Connection, equipotential bonding | |
Connection method | Cable connection/DIN rail |
Connection data | |
Connection method | RJ45/COMBICON |
Connection method IN | RJ45 socket |
Connection method OUT | RJ45 socket |
Connection method IN | MC 1,5/4 |
Connection method OUT | MC 1,5/4 |
Connection technology | Screw connection |
Screw thread | M2 |
Tightening torque | 0.22 Nm |
Stripping length | 7 mm |
Conductor cross section flexible | 0.14 mm² … 1.5 mm² |
Conductor cross section solid | 0.14 mm² … 1.5 mm² |
Conductor cross section AWG | 28 … 16 |
Dimensions | |
Height | 103 mm |
Width | 25 mm |
Depth | 63 mm |
![]() |
|
Environmental Product Compliance | |
Reach and RoHS Compliant | Reach and RoHS Compliant |
Approvals | |
UL Listed EAC |
|
Commercial data | |
Packing unit | 1 |
Weight per piece | 320.0 g |
Country of origin | Germany |
Application Diagrams
Circuit Diagram |
---|
![]() |
Protection Against Surge Voltage |
Digital telecommunications systems (DSL) are safely protected against surge voltage by SHDSL Surge Protectors. Due to the high bandwidth of the surge protectors, the transmission signal is not influenced. Use is possible up to DSL 16000. All signal wires and the ground conductor must be connected to the surge protector according to the connection scheme. Any DIN rail should be grounded.
![]() |